VessConnect “Plug Flow” innovative technology providing patients a safer, more effective and less costly procedure for vascular anastomosis

Cordis

Detalles del proyecto

Objetivo

Proposal title*
VessConnect “Plug & Flow” innovative technology providing every year to 270.000 European patients a safer, more effective and less costly procedure for vascular anastomosis

ACRONYM:

PLUGandFLOW

Free keywords
vascular anastomosis, microvascular anastomosis, microsurgery, NiTiNol, advanced materials, bio-absorbable Shape Memory Polymers, Advanced Material Innovation applied to surgical device, microsurgery

Abstract:
Vascular anastomosis, the surgical union of two blood vessels, has been technically performed in the same way for the last 100 years: suturing both ends of the vessels with microsutures. Even though several devices have appeared to ease the proceeding, none of them could improve traditional techniques. The result is a time-consuming procedure, with a long learning curve, which is not widely spread in private health systems because of its dangers and lack of efficiency and reliability.
Surg Solution’s, is a start-up company founded by two surgeons, one bio-medical engineer and a business consultant, that has designed, prototyped and solicited a PCT patent for a device, VessConnect, that will reduce costs and probabilities of failure in anastomosis procedures. The product, a stent-like device, relies on the shape-memory characteristics of NiTiNol.
Vascular anastomosis is a widely spread surgical procedure used in organ transplants and general reconstruction surgery, among others. Vessconnect has the potential to impact on the health improvement of the 270.000 European patients that we estimate need a surgery involving an anastomosis every year. Surg Solution aims to gain with VessConnect, 45% market-share of microvascular anastomosis in top European Markets in 5 years, generating €18M on revenues by 2021 with a 77% EBITDA margin.
VessConnect is at TRL6. We aim to launch the product by mid 2019, bringing to patients a safer surgery, to surgeons an easier procedure and to the healthcare system a more efficient solution to perform vascu

Acrónimo

PLUGandFLOW

Estado

CLOSED

Tema

SMEInst-02-2016-2017

Palabras Clave

No hay datos disponibles

Coste total

71.429,00 €

Contribución máxima UE

50.000,00 €

Coordinadores

SURG SOLUTIONS SL

BARCELONA, ES

Duración

Fecha de inicio01 de diciembre de 2017
Fecha de finalización31 de mayo de 2018
Proyectos Cordis relacionados