Proyectos europeos
Logo

Functionally Accurate Robotic Surgery

Cordis

Detalles del proyecto

Objetivo

FAROS aims at improving functional accuracy through embedding physical intelligence in surgical robotics. A key motivation for introducing robots in operating rooms has been their ability to deliver superhuman performance. However, for the vast majority of surgical procedures, robotic positioning precision alone is not sufficient to realize the “right gesture”. Indeed, surgical accuracy is a different concept from standard engineering notions such as geometric precision, resolution or sensitivity. This arises from the essence of the surgical tasks: surgeons do not let their gestures be dictated by pure geometric objectives; rather, functional objectives are what they pursue. FAROS explores venues to efficiently embody surgeon-like autonomous behaviour at different levels of granularity. The following key ingredients are foreseen: (1) a rich set of non-visual sensors that form a multifaceted representation of the surgical task; (2) functional models that relate non-conventional sensor signals to functional parameters (e.g. tissue type, quality of tissue or bone, condition of tissue/fluid, tissue damage, perfusion, implant stability, etc.); and (3) functional controllers, obtained through reinforcement learning, that encode physical intelligence and produce sensible autonomous robot actions geared at closing knowledge gaps or optimizing functional performance. This new concept, which we refer to as Functionally Accurate RObotic Surgery (FAROS), will be showcased on two critical spine surgery use cases, namely: pedicle screw placement and endoscopic lumbar discectomy. A compact yet multi-disciplinary team consisting of academics, industry and end-users will collaborate closely to build up robotic controllers that are better suited at delivering functional accuracy in the presence of large variability and disturbances inherent to every surgical act.

Acrónimo

FAROS

Estado

CLOSED

Tema

ICT-47-2020

Palabras Clave

  • Surgical Robotics
  • Non-visual Sensors
  • Decision Making
  • Functional Accuracy

Coste total

2.990.898,75 €

Contribución máxima UE

2.990.898,75 €

Coordinadores

KATHOLIEKE UNIVERSITEIT LEUVEN

LEUVEN, BE

Participantes

SPINEGUARD

Vincennes, FR

SORBONNE UNIVERSITE

PARIS, FR

UNIVERSITAT ZURICH

Zurich, CH

KING'S COLLEGE LONDON

London, UK

CENTRE NATIONAL DE LA RECHERCHE SCIENTIFIQUE CNRS

PARIS, FR

Duración

Fecha de inicio01 de enero de 2021
Fecha de finalización30 de junio de 2024